Sunday, August 30, 2026

Potable water disinfection

Potable Water Disinfection and discard the filter elements 

AMM task 38-10-00-670-002-A

Procedure by the use of Hydrogen peroxide H2O2

38-10-00-670-004-A

Sequence to be followed as under:-

Hot water flushing then Disinfection and again Hot water flushing to be done.

Replacement of the Galley water Filter elements.

Refer AMM 38-12-23-920-802-A

Before replacing the filter,Close the potable water shut off Valve,in the galley release the remaining water.

FIN 6475MM & 6483MM

Filter P/N- Check it's applicability.

Replace the applicable Filter along with its Gasket then carry out the leak check.

For zone/ location of the Filter,refer applicable AMM.

Leak is not permitted.