Potable Water Disinfection and discard the filter elements
AMM task 38-10-00-670-002-A
Procedure by the use of Hydrogen peroxide H2O2
38-10-00-670-004-A
Sequence to be followed as under:-
Hot water flushing then Disinfection and again Hot water flushing to be done.
Replacement of the Galley water Filter elements.
Refer AMM 38-12-23-920-802-A
Before replacing the filter,Close the potable water shut off Valve,in the galley release the remaining water.
FIN 6475MM & 6483MM
Filter P/N- Check it's applicability.
Replace the applicable Filter along with its Gasket then carry out the leak check.
For zone/ location of the Filter,refer applicable AMM.