Any work on TCT or TLT is required to open 413/423 DT Panel.
Once you open this access panel,there is a 90% probability that you find 2 or 3 screws stuck and you need a structure personal to cut the screw or Nut Plate.
TCT FILTER FIN NO -7170HM1/7170HM2
Following are the P/N:-
Screw-NAS1102E3-8
Washer-NAS1169C10L
Nut Plate-NAS1791C3-1
Rivet-CCR264CS3-03/-04
TQ required -13 to 15 lbft-ft
PANEL REPLACEMENT AMM REF:-54-52-11-000/400-002
FILTER P/N-398-21 for Ceo a/c
O-RING P/N-S4165
Anti seize compound -03PBB1
LOCK WIRE-14QDB1
CBs are to be safetied open during the work -
49VU-D11,D12
122VU-Z22,Z23
NOTE :- Ensure that while installing Filter, convex side of the seal touches the Filter
AMM REF:-36-11-43-000/400-008-A
This is a general guidelines,refer applicable AMM for the job.